2×2 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K Integrated Sensor Receptacle 120–277V
2×2 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K Integrated Emergency Backup 120–277V

2×2 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K 120–277V


Quick Answer: Specify this 120–277V 2x2 panel for general office grids. Delivers up to 5,000 lumens with 5-CCT tuning.


Key Features:

  • Grid Compatible: Standard 2x2 T-bar fit.
  • Wattage Selectable: 15W to 40W field settings.
  • 5-CCT Tuning: 3500K to 6500K range.
  • DLC Premium: Qualified for energy utility rebates.

Brand NCLTG
Manufacturer Part Number NC-BPL22-M40W-CCT
DLC Product ID S-KK2HX9
Wattage 15W, 20W, 25W, 30W, 40W
Voltage 120–277V
Lumens 1,950, 2,600, 3,250, 3,810, 5,000
Efficacy 125–130 lm/W
CCT 3500K, 4000K, 5000K, 5700K, 6500K
Dimming 0–10V
Special Features Wattage and CCT Selectable
Certifications cETLus Listed, RoHS Compliant, DLC Premium Listed
Dimensions 23.74" L × 23.74" W × 1.38" H
Warranty 5-Year Limited Warranty

Selection Guidance: Best for standard T-grid ceiling installations in corporate and educational environments. The slim 1.38-inch profile ensures fitment in restricted plenum spaces while providing high-efficacy (130 lm/W) uniform light.


Regular price $34.99 Sale price$29.74 Save $5.25
/
Free shipping calculated at checkout.
  • In stock, ready to ship
  • Backordered, shipping soon

Start here: For the fastest commercial routing, use Request a Project Quote. For the complete intake → documentation → shipping visibility → closeout workflow, see Commercial Project Support.

Call: (800) 357-6860   Email: support@starsandstripeslighting.com

Quick answer: Shipping method, lead time, and tracking visibility vary by product type and carrier (parcel vs. freight/LTL). For commercial receiving requirements, delivery appointments, inspection steps, and documentation, use Shipping Reliability & Fulfillment.

If you’re working against a site schedule, include your ship-to requirements and target date in your quote request: Request a Project Quote.

Quick answer: Returns and restocking are evaluated based on condition, packaging, and manufacturer requirements. Start here for eligibility, restocking expectations, and documentation steps: Returns & Restocking.

Important: Do not ship items back without an approved return request and routing instructions.

Quick answer: Warranty routing depends on product line and the documentation available (order/PO reference, photos, and configuration details). Use Warranty Claims to submit the required information so we can route your claim correctly.

If you’re submitting project closeout records (submittals, IES, warranty docs), see Closeout Documentation.

Quick answer: For common questions about quoting, documentation, shipping visibility, returns, and warranty routing, use our Frequently Asked Questions page.

For a full commercial workflow overview, start here: Commercial Project Support.

Brandon Waldrop, lead commercial lighting specialist

Spec-reviewed for commercial installs

Brandon Waldrop

Lead Commercial Lighting Specialist • Spec Verification + Project Documentation

NCLTG’s 2×2 drop-ceiling panel is reviewed for standard grid fit (2×2 T-bar compatibility), configurable room-by-room output control (15–40W delivering 1,950–5,000 lumens with 5-CCT tuning from 3500K–6500K), and incentive qualification (DLC Premium listing) on 120–277V so small-grid retrofits stay consistent across a property without over-lighting support rooms, mixing color between adjacent spaces, or losing rebate eligibility due to mismatched configuration.

Spec review focus:
Verified for 2×2 T-bar ceiling compatibility to support quick replacement in standard grid systems common to offices, education, and commercial interiors; verified for selectable wattage settings (15W/20W/25W/30W/40W) to right-size illumination by space type and ceiling height without changing fixture platforms; verified for lumen range of 1,950–5,000 lumens to cover typical 2×2 grids while avoiding glare and wasted load in small rooms when higher outputs aren’t needed; verified for 5-CCT tuning (3500K/4000K/5000K/5700K/6500K) to align with building-wide color standards and prevent mixed-CCT patching during phased upgrades; verified for 120–277V electrical compatibility for standard commercial branch circuits across mixed-voltage properties; verified for DLC Premium listing intent to support eligibility for many utility incentive programs where DLC Premium is required.

Verified configuration:
For 2×2 panel retrofits, consistency is a settings and scheduling problem more than a hardware problem: define the watt/CCT standards by room type (e.g., offices vs. corridors vs. storage), then document the “as-built” watt and CCT selections (15/20/25/30/40W and 3500K–6500K) per room so future replacements don’t default to incorrect settings. Keep identical settings across each ceiling plane to prevent brightness and color checkerboarding. If rebates are part of the project, maintain the DLC Premium listing documentation with the as-built schedule and verify the installed settings align with what was submitted—post-install setting changes are a common audit failure point.

Team-backed support: Quotes, photometrics, submittals, shipping visibility, and closeout documentation are supported through Commercial Project Support . Call 800-357-6860.

How this spec is verified


Recently viewed