1×4 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K 120–277V
1×4 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K 120–277V
1×4 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K 120–277V

1×4 LED Drop Ceiling Light 15/20/25/30/40W 1950–5000 Lumens 3500K/4000K/5000K/5700K/6500K 120–277V


Quick Answer: Specify this 120–277V 1x4 panel for narrow hallway and corridor grids. Delivers up to 5,000 lumens with 5-CCT tuning.


Key Features:

  • Narrow Format: Precision 1x4 grid design.
  • Selectable Output: 15W to 40W power settings.
  • Tunable CCT: 3500K to 6500K versatility.
  • High Efficacy: 130 lumens per watt performance.

Brand NCLTG
Manufacturer Part Number NC-BPL14-M40W-CCT
DLC Product ID S-FRVCC0
Wattage 15W, 20W, 25W, 30W, 40W
Voltage 120–277V
Lumens 1,950, 2,600, 3,250, 3,810, 5,000
Efficacy 125–130 lm/W
CCT 3500K, 4000K, 5000K, 5700K, 6500K
Dimming 0–10V
Special Features Wattage and CCT Selectable
Certifications cETLus Listed, RoHS Compliant, DLC Premium Listed
Dimensions 47.76" L × 11.93" W × 1.38" H
Warranty 5-Year Limited Warranty

Selection Guidance: Specified for narrow spatial requirements where 2x2 or 2x4 fixtures are impractical. Provides high-intensity, glare-free illumination with field-selectable wattage to match specific footcandle requirements in transit areas.


Regular price $37.99 Sale price$32.29 Save $5.70
/
Free shipping calculated at checkout.
  • In stock, ready to ship
  • Backordered, shipping soon

Start here: For the fastest commercial routing, use Request a Project Quote. For the complete intake → documentation → shipping visibility → closeout workflow, see Commercial Project Support.

Call: (800) 357-6860   Email: support@starsandstripeslighting.com

Quick answer: Shipping method, lead time, and tracking visibility vary by product type and carrier (parcel vs. freight/LTL). For commercial receiving requirements, delivery appointments, inspection steps, and documentation, use Shipping Reliability & Fulfillment.

If you’re working against a site schedule, include your ship-to requirements and target date in your quote request: Request a Project Quote.

Quick answer: Returns and restocking are evaluated based on condition, packaging, and manufacturer requirements. Start here for eligibility, restocking expectations, and documentation steps: Returns & Restocking.

Important: Do not ship items back without an approved return request and routing instructions.

Quick answer: Warranty routing depends on product line and the documentation available (order/PO reference, photos, and configuration details). Use Warranty Claims to submit the required information so we can route your claim correctly.

If you’re submitting project closeout records (submittals, IES, warranty docs), see Closeout Documentation.

Quick answer: For common questions about quoting, documentation, shipping visibility, returns, and warranty routing, use our Frequently Asked Questions page.

For a full commercial workflow overview, start here: Commercial Project Support.

Brandon Waldrop, lead commercial lighting specialist

Spec-reviewed for commercial installs

Brandon Waldrop

Lead Commercial Lighting Specialist • Spec Verification + Project Documentation

NCLTG’s 1×4 drop-ceiling panel is reviewed for narrow-grid deployment (1×4 format for corridor and row layouts), controlled output tuning (15/20/25/30/40W delivering 1,950–5,000 lumens), and field-matched color standards (5-CCT from 3500K–6500K) on 120–277V with ~130 lm/W class efficacy so linear ceiling runs stay uniform without end-to-end brightness steps, mixed-CCT “striping,” or wasted load in long corridors.

Spec review focus:
Verified for 1×4 narrow-format intent to align with corridor grids, circulation paths, and linear room layouts where 2×4 panels can create uneven spacing and patchy ceiling appearance; verified for selectable wattage steps (15W/20W/25W/30W/40W) to right-size light levels by corridor width, ceiling height, and reflectance without changing fixture platforms; verified for lumen packages of 1,950–5,000 lumens to support continuous-run ceilings and narrow bays where excessive output typically drives glare and reflected hotspotting; verified for tunable CCT range (3500K/4000K/5000K/5700K/6500K) to match site standards across departments and prevent visible color mismatch when extending an existing run; verified for 120–277V electrical compatibility for standard commercial branch circuits; verified for efficacy intent around 130 lm/W to reduce connected load while meeting target illumination when spacing and watt selection are coordinated.

Verified configuration:
In 1×4 grids, inconsistency reads as a “broken run”: document the “as-built” watt setting (15/20/25/30/40W) and CCT selection (3500K–6500K) by corridor or row segment, and keep identical settings across each continuous line to avoid visible brightness and color steps. If different light levels are required (e.g., corridor vs. adjacent rooms), make the change at a clear boundary and note it on the reflected ceiling plan so maintenance doesn’t mix settings later. After commissioning, perform a simple walk-through check from both directions—narrow-format panels can show glare or banding if one segment is set higher or a different CCT than the rest.

Team-backed support: Quotes, photometrics, submittals, shipping visibility, and closeout documentation are supported through Commercial Project Support . Call 800-357-6860.

How this spec is verified


Recently viewed